To adjust the start delay at the stopping floor
Adjuster: #1 · Function: bypass
How to adjust
- ↻ Clockwise
- Shorter delay
- ↺ Counterclockwise
- Longer delay
Shows which adjuster to turn in which direction for each desired movement.
Adjuster: #1 · Function: bypass
Adjuster: S · Function: pressure adjustment
Close the oil shut-off valve, obtain the desired pressure, then lock the bolt
Adjuster: #2 · Function: upward acceleration
Adjusting #2 affects #3 and #4, so do not adjust it if the upward acceleration is satisfactory
Adjuster: #3 · Function: upward deceleration
Once sufficient deceleration is achieved, fix the safety switch
At a travel speed of 0.5m/sec, the distance between the safety switch and the landing switch is 0.5m
Adjuster: #4 · Function: upward landing
Adjusts the creep speed. Speed V = 5 ~ 7cm
Adjuster: #5 · Function: upward stop
#5 only has an effect if the pump is kept running about 0.5 seconds longer via a time relay
※ Adjust only when the oil is cold
※ If adjusted too soft, the car may land at an inaccurate position
Adjuster: #6 · Function: downward acceleration
#8 affects #6, so readjust #6 if necessary
Adjuster: #7 · Function: downward travel
The downward travel speed of the car is determined by the setting of #7
Adjuster: #8 · Function: downward deceleration
Soft stop test → when making an electrical emergency stop at full downward speed, cutting the magnetization of coil C and coil D must bring the car to a smooth stop within 20cm
Adjuster: #9 · Function: downward landing